Skip to main content

Potentiostat/Galvanostat

Metrohm Group PGSTAT 128N
Intended for electrochemical tests: potentiostatic and potentiodynamic such as cyclic voltammetry, chronoamperometry, corrosion tests. Maximum current up to 800 mA with a voltage of 12 V.
Sanja Stevanović
sanjas@ihtm.bg.ac.rs
Karnegijeva 4

Potentiostat/Galvanostat

Metrohm Group PGSTAT 128N
Intended for electrochemical tests: potentiostatic and potentiodynamic such as cyclic voltammetry, chronoamperometry, corrosion tests. Maximum current up to 800 mA with a voltage of 12 V. Upgraded with an EQCM (quartz micro balance) module
Dušan Tripković
dusan@ihtm.bg.ac.rs
Karnegijeva 4

Micro scale module

Metrohm EQCM - Electrochemical Quartz Crystal Microbalance
The EQCM module allows performing electrochemical experiments on microscale quartz crystals. The EQCM module measures the change in mass per unit area by recording the change in resonant frequency of a quartz crystal oscillator. It enables measurement in the μg / cm2 range.
Sanja Stevanović
sanjas@ihtm.bg.ac.rs
Karnegijeva 4

Pullo dynamic voltameter

TACON GROUP VOLTALAB PG2 402 Radiometer
Intended for electrochemical tests: potentiostatic, potentiodynamic tests and impedance. Maximum voltage ± 30 V, maximum current ± 1 A, measurement period 500 μs, maximum scan 20 V/s; for electrochemical impedance: maximum frequency 100 kHz, minimum frequency 1 mHz
Jelena Lović, jelena.lović@ihtm.bg.ac.rs
Karnegijeva 4

Scanning probe microscope - SPM and AFM

VEECO Digital instruments NanoScope MultiMode SPM
Intended for examination of surface morphology using scanning tunneling microscopy and atomic force microscopy.
Sanja Stevanović
sanjas@ihtm.bg.ac.rs
Karnegijeva 4

Potentiostat/Galvanostat

BioLogic Science Instruments SP-240
Universal electrochemical station intended for electrochemical tests: cyclic voltammetry, impedance, etc. Minimum current: +/-100 pA, Maximum current: +/- 4 A; Voltage range: -10 V to +14 V; Electrochemical impedance (EIS): up to 7 MHz
Vladimir Panić, panic@ihtm.bg.ac.rs
Nјegoševa 12

Potentiostat/Galvanostat

BioLogic Science Instruments SP-200
Universal electrochemical station intended for electrochemical tests: cyclic voltammetry, impedance, etc. Minimum current: +/-100 pA, Maximum current: +/- 500 mA; Voltage range: -10 V to +10 V; Electrochemical impedance: up to 7 MHz
Maja Obradović, obradovic@ihtm.bg.ac.rs
Karnegijeva 4

Optical microscope with camera

Olympus CX41
It is intended for examining the morphology of conductive and non-conductive surfaces; magnifications from 50× to 500×, CELL A software.
Nebojša Nikolić, nnikolic@ihtm.bg.ac.rs
Karnegijeva 4

Water purification system

Millipore A10 I Millipore Elix 10
A water purification system consisting of two components - Advantage A10 and Elix 10. It enables obtaining ultrapure, type 1 water, resistance at 25 oC of 18.2 MΩcm.
Dušan Tripković, dusan@ihtm.bg.ac.rs
Karnegijeva 4

Spectrophotometer

Shimadzu UV2600
Intended for testing primarily clinical samples; ultraviolet and visible part of the region, 185-900 nm, software package.
Jelena Lović, jelena.lović@ihtm.bg.ac.rs
Karnegijeva 4

Centrifuge

Hettich Universal 320
Phase separation in solid-liquid mixtures at rotation speeds up to 12000 rpm.
Vladimir Panić
panic@ihtm.bg.ac.rs
Nјegoševa 12

Potentiostat/Galvanostat

GAMRY INTERFACE 1010E
Intended for electrochemical tests: cyclic voltammetry, corrosion measurements, chronoamperometric measurements. Maximum current - ±1 A Maximum applied potential - ±11 V EIS 10 μHz - 2 MHz Maksimalna struja - ±1 A Maksimalni primenjeni potencijal - ±11 V EIS 10 μHz - 2 MHz
Vesna Cvetković, v.cvetkovic@ihtm.bg.ac.rs
Nјegoševa 12

Potentiostat/Galvanostat

GAMRY INTERFACE 1010E
Intended for electrochemical tests: cyclic voltammetry, corrosion measurements, polarization resistance measurements, chronoamperometric measurements. Maximum current - ±1 A Maximum applied potential - ±11 V EIS 10 μHz - 2 MHz
Bojana Radojković bojana.radojkovic@ihtm.bg.ac.rs
Karnegijeva 4